You should not install any piece of Vitreous with-in 3 x the internal diameter from combustible material eg: plaster board ceilings/wood etc, a 6" diameter piece of Vitreous should be 18" away from combustible materials ,
Each joint made should be sealed with Fire cement. Vitreous Flue pipe is only to be used as a connecting piece of flue between the appliance (EG: woodstove) and the flue liner or chimney stack.
Please make sure you buy the correct Adaptor to connect your Stove pipe to Flexible liner or Twin Wall Flue System.
Recommended Fuels:
Gas, Oil, Solid Fuels, Wood, Pellets, Peat
Building Regulations :
We recommend that all installations are carried out by a qualified chimney installer.